TP00952
November 26, 2001 33
Trouble Probable Cause Remedy
LONG HARVEST CYCLES A. Ice weight set too light. A. Adjust bridge per adjustment
instructions.
B. Unit not level. B. Level the unit.
C. Water curtain movement
restricted.
C. Remove restriction.
D. Low head pressure: ambient
too low.
D. Minimum ambient temperature
50_F (10_C).
E. Low head pressure; water
valve set too low (water cooled
units only) or leaking during
harvest.
E. Adjust water regulator valve or
replace (260 to 271 PSI).
F. Scale build-up on evaporator. F. Clean per instructions.
G. Hot gas solenoid valve not
opening. Slow rise of low side
pressure.
G. Replace valve.
H. Expansion valve leaking. H. Replace valve.
SOFT WHITE ICE OR WATER
PUMP NOT PUMPING
A. Distribution tube or water
system scaled.
A. Clean distribution system as
required.
B. Water temperature too cold. B. 50_F (10_C) minimum.
C. Inadequate water system;
water pressure too low (below
20 PSI).
C. Correct.
D. Inadequate water system; fill
valve plugged or damaged.
Water supply filter plugged.
D. Replace.