Start-Up Procedure
Page 15
Bin Control Operation
The bin control is used to shut the machine off when the bin fills with ice. The bin control must be checked upon
installation or initial start-up and when performing maintenance.
There is one bin switch for each evaporator. The actuator arm of the bin switch comes in contact with the splash
curtain. When the bin is full of ice, the splash curtain is held open when ice drops off of the evaporator. This releases
the pressure of the bin switch actuator arm allowing the switch to open.
Single evaporator machines: (Including the CCM1530) If the bin switch opens during freeze or the first part of
harvest, relay 2 bypasses the bin switch and the machine will continue running. If the bin switch is opened during
harvest when the cam switch is lifted onto the high part of the cam, the machine will shut off. When the bin switch
closes again, the machine will restart.
Dual evaporator machines: If either bin switch opens during the freeze cycle, the machine will shut off. Relay 1 and
relay 2 will bypass the bin switches during defrost. If either bin switch is open when the machine returns to the freeze
cycle, the machine will shut off.
Undercounter machines: A thermostatic bin control is used on the undercounter
models. The bin thermostat is located in the control box with a capillary tube,
which is in a brass thermo-well mounted to the water trough. When ice comes in
contact with the capillary tube thermo-well, the bin thermostat opens and the
machine will shut off.
Bin Control Adjustment
All Models (Except Undercounter Models): Check the bin switch for proper
adjustment by swinging the bottom of the curtain away from the evaporator.
Slowly bring the curtain towards the evaporator. The switch should close when
the bottom edge of the curtain is even with the outer edge of the water trough.
Adjust the switch by loosening the nuts that hold the switch in place. Move the
switch to the proper position and retighten the nuts. Recheck the adjustment.
Undercounter Models and CCM1530
Hold ice against the brass thermal-well making sure the ice is in contact with at
least 6 inches (15 cm) of the thermal-well. The bin control should open in
approximately 1 minute. Remove the ice. The bin control should close in
approximately 3 minutes. If a
major adjustment is required,
turn the adjustment screw
counterclockwise (warmer) until it
stops then turn the adjustment
screw clockwise (colder) 1/8 of a
turn. This should put the control
close to the proper adjustment,
recheck and make a minor
adjustment if needed. If a minor
adjustment is required, turn the
adjustment screw clockwise
(colder) or counterclockwise
(warmer).
The bin switch
contacts must be
closed when the
bottom edge of the
curtain is flush with
the edge of the
water trough
Eva
orator
S
lash Curtain
Bin Switch
Adjustment
Nuts
Thermal -well
Thermostatic
Bin Control