Cornelius I Series Instrukcja Obsługi

Przeglądaj online lub pobierz Instrukcja Obsługi dla Kostkarki do lodu Cornelius I Series. Cornelius I Series Service manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
TD 204(Metric)
ICE MAKER
POCKET GUIDE
“I” SERIES CUBE
ICE MAKERS
IMI CORNELIUS
One Cornelius Place
Anoka, MN 55303
1–800–238–3600
Przeglądanie stron 0
1 2 3 4 5 6 ... 65 66

Podsumowanie treści

Strona 1 - ICE MAKERS

TD 204(Metric)ICE MAKERPOCKET GUIDE“I” SERIES CUBEICE MAKERSIMI CORNELIUSOne Cornelius PlaceAnoka, MN 553031–800–238–3600

Strona 2 - TABLE OF CONTENTS

7 TD 204MODEL IAC1230 IWC1230 IRC1230 IAC1448 IWC1448 IRC1448UNIT ELEC.Volts 230 230 230 230 230 230Phase 1 1 1 1 1 1Hertz 60 60 60 60 60 60No. Wires

Strona 3 - TABLE OF CONTENTS (CONT’D)

8TD 204COMPRESSOR (CONT’D)Hertz 60 60 60 60 60 60LRA 96 96 96 95.6 95.6 95.6RLA 13.5 13.5 13.5 23.9 23.9 23.9CONDENSER FAN MOTOR (Air-Cooled System on

Strona 4

9 TD 204MODEL IRC630 IRC830. IRC1230 IRC1448UNITVolts 230 230 230 230Phase 1 1 1 1Hertz 60 60 60 60No. Wires 2+ground 2+ground 2+ground 2+groundMIN. C

Strona 5 - Serial Plate Locations

10TD 204Remote CondenserMODEL CR800 CR1200 CR1400Volts 230 230 230Phase 1 1 1Hertz 60 60 60Amps 1.0 1.0 1.0Output, HP 1/6 1/6 1/6Max. fuse size, Amps

Strona 6 - Serial Number Defined

11 TD 204ICE CAPACITY INFORMATIONIce CapacityIce capacity of any ice maker is affected by many operating condi-tions, such as water and air temperatur

Strona 7 - Electrical Specification

12TD 204ADJUSTMENT OF ICE BRIDGETHICKNESSTOP ROW.95 CM - 1.59 CMDIMPLECENTER.32 CM BRIDGEBOTTOM 2 ROWS.48 CM - .64 CM BRIDGE For optimum ice productio

Strona 8

13 TD 204Should a different thickness of the bridge be desired, it will be re-quired to adjust the ice thickness “POT”, located on the circuitboard, a

Strona 9

14TD 204IAC322/IAC330FREEZE CYCLE HARVEST CYCLEAMBIENTTEMP_CWATERTEMP_CHEADPRESSUREkPaSUCTION PRESSUREkPaCYCLE TIMEMin:SecHEAD PRESSUREkPaSUCTIONPRESS

Strona 10

15 TD 204IWC322/IWC330FREEZE CYCLE HARVEST CYCLEAMBIENTTEMP_CWATERTEMP_CHEADPRESSUREkPaSUCTION PRESSUREkPaCYCLE TIMEMin:SecHEAD PRESSUREkPaSUCTIONPRES

Strona 11 - (Air-Cooled System only) or

16TD 204IAC522/IAC530FREEZE CYCLE HARVEST CYCLEAMBIENTTEMP_CWATERTEMP_CHEADPRESSUREkPaSUCTION PRESSUREkPaCYCLE TIMEMin:SecHEAD PRESSUREkPaSUCTIONPRESS

Strona 12

TD 204iTABLE OF CONTENTSPAGEintroduction 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Original Owner, End-user respons

Strona 13 - Remote Condenser

17 TD 204IWC522/IWC530FREEZE CYCLE HARVEST CYCLEAMBIENTTEMP_CWATERTEMP_CHEADPRESSUREkPaSUCTION PRESSUREkPaCYCLE TIMEMin:SecHEAD PRESSUREkPaSUCTIONPRES

Strona 14 - Ice Production Check

18TD 204IAC630FREEZE CYCLE HARVEST CYCLEAMBIENTTEMP_CWATERTEMP_CHEADPRESSUREkPaSUCTION PRESSUREkPaCYCLE TIMEMin:SecHEAD PRESSUREkPaSUCTIONPRESSUREkPaC

Strona 15 - THICKNESS

19 TD 204IWC630FREEZE CYCLE HARVEST CYCLEAMBIENTTEMP_CWATERTEMP_CHEADPRESSUREkPaSUCTION PRESSUREkPaCYCLE TIMEMin:SecHEAD PRESSUREkPaSUCTIONPRESSUREkPa

Strona 16

20TD 204IRC630FREEZE CYCLE HARVEST CYCLEAMBIENTTEMP_CWATERTEMP_CHEADPRESSUREkPaSUCTION PRESSUREkPaCYCLE TIMEMin:SecHEAD PRESSUREkPaSUCTIONPRESSUREkPaC

Strona 17 - IAC322/IAC330

21 TD 204IAC830FREEZE CYCLE HARVEST CYCLEAMBIENTTEMP_CWATERTEMP_CHEADPRESSUREkPaSUCTION PRESSUREkPaCYCLE TIMEMin:SecHEAD PRESSUREkPaSUCTIONPRESSUREkPa

Strona 18 - IWC322/IWC330

22TD 204IWC830FREEZE CYCLE HARVEST CYCLEAMBIENTTEMP_CWATERTEMP_CHEADPRESSUREkPaSUCTION PRESSUREkPaCYCLE TIMEMin:SecHEAD PRESSUREkPaSUCTIONPRESSUREkPaC

Strona 19 - IAC522/IAC530

23 TD 204IRC830FREEZE CYCLE HARVEST CYCLEAMBIENTTEMP_CWATERTEMP_CHEADPRESSUREkPaSUCTION PRESSUREkPaCYCLE TIMEMin:SecHEAD PRESSUREkPaSUCTIONPRESSUREkPa

Strona 20 - IWC522/IWC530

24TD 204IAC1030FREEZE CYCLE HARVEST CYCLEAMBIENTTEMP_CWATERTEMP_CHEADPRESSUREkPaSUCTION PRESSUREkPaCYCLE TIMEMin:SecHEAD PRESSUREkPaSUCTIONPRESSUREkPa

Strona 21

25 TD 204IWC1030FREEZE CYCLE HARVEST CYCLEAMBIENTTEMP_CWATERTEMP_CHEADPRESSUREkPaSUCTION PRESSUREkPaCYCLE TIMEMin:SecHEAD PRESSUREkPaSUCTIONPRESSUREkP

Strona 22

26TD 204IRC1030FREEZE CYCLE HARVEST CYCLEAMBIENTTEMP_CWATERTEMP_CHEADPRESSUREkPaSUCTION PRESSUREkPaCYCLE TIMEMin:SecHEAD PRESSUREkPaSUCTIONPRESSUREkPa

Strona 23

iiTD 204TABLE OF CONTENTS (CONT’D)PAGESensors 37. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sensor [Thermisto

Strona 24

27 TD 204IAC1230FREEZE CYCLE HARVEST CYCLEAMBIENTTEMP_CWATERTEMP_CHEADPRESSUREkPaSUCTION PRESSUREkPaCYCLE TIMEMin:SecHEAD PRESSUREkPaSUCTIONPRESSUREkP

Strona 25

28TD 204IWC1230FREEZE CYCLE HARVEST CYCLEAMBIENTTEMP_CWATERTEMP_CHEADPRESSUREkPaSUCTION PRESSUREkPaCYCLE TIMEMin:SecHEAD PRESSUREkPaSUCTIONPRESSUREkPa

Strona 26

29 TD 204IRC1230FREEZE CYCLE HARVEST CYCLEAMBIENTTEMP_CWATERTEMP_CHEADPRESSUREkPaSUCTION PRESSUREkPaCYCLE TIMEMin:SecHEAD PRESSUREkPaSUCTIONPRESSUREkP

Strona 27

30TD 204IAC1448FREEZE CYCLE HARVEST CYCLEAMBIENTTEMP_CWATERTEMP_CHEADPRESSUREkPaSUCTION PRESSUREkPaCYCLE TIMEMin:SecHEAD PRESSUREkPaSUCTIONPRESSUREkPa

Strona 28

31 TD 204IWC1448FREEZE CYCLE HARVEST CYCLEAMBIENTTEMP_CWATERTEMP_CHEADPRESSUREkPaSUCTION PRESSUREkPaCYCLE TIMEMin:SecHEAD PRESSUREkPaSUCTIONPRESSUREkP

Strona 29

32TD 204IRC1448FREEZE CYCLE HARVEST CYCLEAMBIENTTEMP_CWATERTEMP_CHEADPRESSUREkPaSUCTION PRESSUREkPaCYCLE TIMEMin:SecHEAD PRESSUREkPaSUCTIONPRESSUREkPa

Strona 30

33 TD 204“I” SERIESSEQUENCE OF OPERATIONWhen the on off clean switch is pushed to the on position the com-pressor will start after a 2 second delay. T

Strona 31

34TD 204LED IndicatorsThe LEDs are board circuit indicators. If the LED in the functionalboard circuit is complete, check component.Example: Contactor

Strona 32

35 TD 204LED STATUS INDICATOR CHARTD6 Green LED Condenser FanD10 Yellow LED Left Water CurtainD11 Green LED Hot Gas ValveD12 Green LED Water PumpD13 Y

Strona 33

36TD 204Harvest ModeD11Green LED(on) Three seconds after waterdump valve becomes acĆtive, the hot gas valve beĆcomes activeD12Green LED(on)15sec.Fifte

Strona 34

1 TD 204introductionThis guide is published as an aid to the Service Technician. It is notintended to replace the service manual. In it you will find

Strona 35

37 TD 204Error LED (cont’d)D5Red LEDFlashĆing,1/secCONDENSER OPENTHERMISTOR CIRCUIT (AirCooled only) Ć Thermistoropen / broken wire / poorconnection.

Strona 36 - Circuit Board

38TD 204Dump Cycle OptionsYou have the option of selecting dump cycle intervals of:S every cycle; (Standard setting fromfactory)S every 3rd cycle;S e

Strona 37 - LED Indicators

39 TD 204Condenser Fan Cycling Control(Intergal Condenser)The condenser fan on air-cooled cubers is cycled by the circuitboard. The condenser sensor s

Strona 38 - LED STATUS INDICATOR CHART

40TD 204YLYLRH Evap.WaterDumpValveContactorWaterPump135724230v115vVoltageSelectorSwitchGRLH Evap.CondenserplugSuction plugTest PlugOptionsPlugAdjustab

Strona 39

41 TD 204Sensor [Thermistor] DiagnosisSensorsCondenser or suction line – Turn Cuber power switch OFF. Discon-nect sensor plug from board. Use digital

Strona 40 - Test Plug

42TD 20410. Should sensor (thermistor) pass the voltage test pro-ceed to the control board diagnosis for LED sequence(see page 39).NOTE: The sensor co

Strona 41 - Dump Cycle Options

43 TD 204Should adjustment be required, the valve has an adjustment stem onthe top of the valve. After allowing the cuber to operate for 10 min-utes i

Strona 42 - Circuit Board Diagnosis

44TD 204Flow control washer flat side upService Stem ValvesWhen closing the service stem valves to remove your gauge andmanifold set always close the

Strona 43

45 TD 204DIAGNOSISStarving TXV - Product Symptoms1. Suction pressure lower than normal for the operatingconditions.2. Ice production lower than normal

Strona 44

46TD 204Head Pressure Control Valve [Headmaster]/Fan Cycle Switch(Remote Units Only)dischargereceivercondenserabove 70°Fnormaldis-chargereceiverconden

Strona 45 - Water Regulating Valve

2TD 204Serial Plate LocationsExterior: Left side, Lower Front corner.Interior: Firewall, Front.Model and Serial Number DefinedIAC 1230IAC1230Product I

Strona 46 - Float Valve with Flow Washer

47 TD 204maintain a receiver outlet pressure equal to or above the dome pres-sure setting of the valve the dome pressure will force the valve por-tage

Strona 47 - Thermostatic Expansion Valves

48TD 204defective. The overload protector, start and/or run capacitor, relay,circuit board, safety controls, etc.1. Check voltage at compressor termin

Strona 48 - DIAGNOSIS

49 TD 204the rating on the defective original capacitor being replaced. Voltageshould always try and be matched, if it cannot be it is acceptable toin

Strona 49 - (Remote Units Only)

50TD 204S Compressor mechanical problemsS Low Refrigerant ChargeMoisture ContaminationWith the major changes in refrigerants in today’s marketplace an

Strona 50 - Check-Out Procedure

51 TD 204Readings in the range listed below 100 Meg–Ohm would be an indi-cator that the system being tested may have a contamination prob-lem. Where d

Strona 51 - Capacitors

52STARTORCAPACITORCOMPRESSORWHWHWH2RDYLRSCCOMPRESSOROVERLOADEXTERNAL1WH5BKFAN MOTORCONDENSER(A/C ONLY)WHBLWATER DUMPMVALVESTART RELAYPOTENTIAL115 VAC2

Strona 52 - Compressor

5353 TD 202RDSTARTORCAPACITORCOMPRESSORWHWHWHCOMPRESSORYL2 RUNCAPACITORRDYLRSCCOMPRESSOROVERLOADEXTERNAL 30 mfd 440 VAC1WH5BKFAN MOTORCONDENSER(A/C ON

Strona 53 - Moisture Contamination

54250 VACCAPACITORSTARTORCOMPRESSOR145-174 mfdRDWHRDYLCAPACITORRUNCOMPRESSORRDRDYLCRSOVERLOADEXTERNALCOMPRESSOR21WH5VALVEBKBKBLWATER DUMPMFAN MOTORSTA

Strona 54

55RD330 VACCAPACITORSTARTORCOMPRESSOR189-227 mfdRDWHRDCAPACITORRUNYLCOMPRESSORRDRDYLRSCOMPRESSOROVERLOADEXTERNAL2WH15CONDENSORBKBKFAN MOTORS(A/C ONLY)

Strona 55

56RD330 VACCAPACITORSTARTORCOMPRESSOR189-227 mfdRDWHRUNYLRDYLCAPACITORRDRSCCOMPRESSORCOMPRESSOROVERLOADEXTERNAL2WH15WHMBKBLWATER DUMPFAN MOTORVALVESTA

Strona 56 - 53 TD 202

3 TD 204Serial Number Defined after January 1, 1995AF 95 01 BC 0000Engchange levelyear Month ProductCodeUnitSerial NumberEngineering change level can

Strona 57

57BKCAPACITORRED2 mfd 440 VACBKGR208/230 VOLTS 60 HZBKGRRDFAN CYCLINGSWITCHRDRDMFAN MOTORCONDENSORCR800, CR1200, & CR1400 REMOTE CONDENSERSHEAT

Strona 58

58TD 204TROUBLESHOOTINGIMPORTANT: Only qualified personnel should service inter-nal components or electrical wiring.Trouble Probable Cause RemedyCUBER

Strona 59

59 TD 204Trouble RemedyProbable CauseCUBER NOTOPERATINGINDICATORLIGHTS “OFF”,POWER TOTHE CIRCUITBOARDA. Magnet notin proximityswitch field.A. Water cu

Strona 60

60TD 204Trouble RemedyProbable CauseCOMPRESSORRUNS BUTDOES NOTCOOL, CIRCUITBOARDINDICATORLIGHTS “ON”A. Low charge. A. Leak check –Recharge.B. Hot gass

Strona 61 - TROUBLESHOOTING

61 TD 204Trouble RemedyProbable CauseE. Expansionvalve failure(will not pulldown).E. Tighten bulb,replace asneeded, Seecheck-outprocedure.CUBERREMAINS

Strona 62

62TD 204Cleaning ProceduresApproved ice machine cleaners by brand names:S Lime-A-WayS Calgon Nickel Safe (green coloronly)NOTE: All ice machine clean

Strona 63

63 TD 2044. Return the water curtain(s) to their proper operatingposition.5. Add 88.8 Mil. for a single evaporator, or 147.9 Mil.for a dual evaporato

Strona 64

4TD 204Electrical SpecificationMODELIAC322/330IWC322/330IAC522/530IWC522/530UNITVolts 115 115 115 115Phase 1 1 1 1Hertz 60 60 60 60No. Wires 2+ground

Strona 65 - Evaporator

5 TD 204MODEL IAC630 IWC630 IRC630 IAC830 IWC830 IRC830UNIT ELEC.Volts 230 230 230 230 230 230Phase 1 1 1 1 1 1Hertz 60 60 60 60 60 60No. Wires 2+grou

Strona 66 - Sanitizing Procedures

6TD 204COMPRESSOR (CONT’D)Hertz 60 60 60 60 60 60LRA 69 69 69 61 61 61RLA 8.8 8.8 8.8 12.5 12.5 12.5CONDENSER FAN MOTOR (Air-Cooled System only) orAIR

Komentarze do niniejszej Instrukcji