FlavorFusion™ Training Manual
© 2004-2005, IMI Cornelius Inc. - 3 - Publication Number: TP01070
PROGRAMMING
The programming mode is exactly the same for both brand and bonus keypads.
To enter the programming mode, press and hold the two program buttons (see FIGURE 3) at the top of
the keypad for approximately 4 seconds. All keypad LEDs will flash off for approximately 1 second to
indicate the start of the programming mode.
To exit programming mode, press and hold the two program buttons for approximately 4 seconds. All
keypad LEDs will flash off for approximately 1 second, resuming normal operation mode.
Programming Mode Flashing Sequences
Once in programming mode, each dispense button LED flashes in a sequence cycle according to one (1)
of six (6) dispense types. For Brand Keypads, only dispense types 1 and 2 are used. For Bonus Flavor
Keypads, dispense types 3 through 6 are used. The six (6) dispense types are described below, and
shown in a timing diagram in FIGURE 1:
• Dispense Type 1, Carbonated water dispense: Solid LED
• Dispense Type 2, Non-carbonated dispense: Flashing LED 1.5 seconds ON, 1.5 seconds OFF
• Dispense Type 3, 1-second flavor shot: LED flashes once for ¼ second, followed by 3 seconds
OFF
• Dispense Type 4, 2-second flavor shot: LED flashes twice for ¼ second ON, ½ second OFF,
followed by 3 seconds OFF
• Dispense Type 5, 3-second flavor shot: LED flashes three (3) times for ¼ second ON, ½ second
OFF, followed by 3 seconds OFF
• Dispense Type 6, 4-second flavor shot: LED flashes four (4) times for ¼ second ON, ½ second
OFF, followed by 3 seconds OFF
FIGURE 1
1. Carbonated water dispense
2. Non-carbonated dispense
3. 1-second flavor shot
012345
Time
(seconds)
Start
proramming
mode
Exit
programming
mode
4. 2-second flavor shot
5. 3-second flavor shot
6. 4-second flavor shot