UC 150 Ice Dispenser Operator’s Manual
© 1999-2014, Cornelius Inc. - 5 - Publication Number: 620917311
INSTALLATION INSTRUCTIONS
!
WARNING:
It is the responsibility of the installer to ensure that the water supply to the dispensing equipment is provided with
protection against backflow by an air gap as defined in ANSI/ASME A112. 1.2-1976; or an approved vacuum breaker
or other such method as proved effective by test and must comply with all federal, state and local codes.
Failure to comply could result in serious injury, death or damage to the equipment.
Water pipe connections and fixtures directly connected to a potable water supply shall be sized, installed, and
maintained according to federal, state and local laws.
1. Locate the dispenser indoors on a level counter top.
A. COUNTER MOUNTING
The ice dispenser must be sealed to the counter. The template drawing indicates the opening that must
be cut in the counter. Locate the desired position for the dispenser, then mark the outline dimensions on
the counter using the template drawings. Cut openings in counter.
Apply a continuous bead of NSF International (NSF) listed silastic sealant (Dow 732 or equal) approximately
1/4” inside of the unit outline dimensions and around all openings. Then, position the unit on the
counter within the outline dimensions. All excess sealant must be wiped away immediately.
2. The drain tube is routed through the large opening in the bottom of the unit. See the MOUNTING TEMPLATE
(page 4) for locating the required clearance hole in the counter for these utility lines. The power cord is routed
through the holes in the side of the unit.
3. SINK DRAIN ASSEMBLY: Connect the drain tube to an open drain. Additional drain tubing is provided with the
unit. The drain tube must continuously pitch downward and contain no “traps” or improper drainage will result.
A. Use 3/4’nominal plastic pipe.
B. To assure proper drainage, do not allow “trap” to form in drain line. Be sure drain line runs flat with bottom of
dispenser.
4. Clean the hopper interior (see CLEANING INSTRUCTIONS in Operator’s Manual).
5. Connect the power cord to a 120 volt, 60 cycle, 15-Amp, 3-wire grounded receptacle.