6
630460070INS
ELECTRICAL
1. All wiring and connections must conform to national and local electrical codes.
2. Wire size and circuit protection must conform to specifications and cuber must be on a separate electrical
circuit.
3. Cuber must be grounded for the safety requirements.
4. A manual disconnect in a convenient location to the cuber must be installed.
INSTALLATION CHECK POINTS.
IMPORTANT: For the Ice Cube Machine to operate properly, the front and back panels must be in place
on the machine. When the Ice Cube Machine is operated without the panels in place, airflow across
the condenser coils is affected, causing pressure variations. These pressure variations can result in
low or a failed ice harvest.
1. Has bin and cuber been leveled and sanitized?
2. Does electrical and plumbing meet code requirements?
3. Check correct operation water level in the water pan.
4. Are drain lines separate and vented?
5. Is there 6” clearance in the front of the machine for proper air circulation?
6. Does the ice harvest switch move freely, and does the float valve shut off incoming water to water pan?
7. Vigorously rub the stainless steel water plate(s), on top of the evaporator(s), with scotch-brite pad to re-
move any oxidation and improve the ability of the water to properly track across plain.
OPERATING WATER LEVEL
SINGLE EVAPORATOR
1.5”
WATER PAN RIGHT SIDE VIEW
FIGURE 3. SINGLE EVAPORATOR WATER LEVEL