Cornelius I Series 224 Instrukcja Instalacji Strona 15

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 18
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 14
11
630460070INS
CIRCUIT BOARD SETTING
Figure 6 shows the setting of circuit board. There are dump cycle dip switch (S3) and curtain selection dip
switch (SW4) in the circuit board. Even though no water curtain equipped in IACS224 and IWCs224, “single cur-
tain connection” on SW4 need to be selected.
Transformer
RD
Error
OFF
OFF
OFF
ON
ON
ON
SW4
SW4
SW4
5
6
YL
YL
YL
YL
S3–1
S3–2
OFF
ON
GR
Comp.
Micro Processor
4 Curtain Switch Connected To Any
Bin Connector (J4–J7) (FACTORY
SETTING AS RECEIVED)
Suction Line Sensor
Bridge thickness pot.
Dump Cycle Dip Switch
Water Curtain
Dip Switch
S3–1
S3–2
On
Off
On
1 2 3
Off
Curtain
Selection
Switch
1
2
3
4
In
Out
Com
Stack
Bin
Switches
External Error LED
Connection
Triac
5 Curtain Switch Must Be Connected To
J4 and J5, J6, J7.
6 Curtain Switch Must Be Connected
To J4, J5, J6 and J7)
SINGLE CURTAIN DUAL CURTAIN FOUR CURTAIN
1
S3–1
OFF
ON
2
S3–1
OFF
ON
3
S3–1
OFF
ON
4
S3-1 S3-2
1 OFF OFF Dump Every Harvest (FACTORY SETTING AS RECEIVED)
2 ON OFF Dump Every Third Harvest
3 OFF ON Dump Every Seventh Harvest
S3–2
S3–2
S3–2
Condenser Sensor
Harvest Voltage Set point pins 2
and 3 Factory setting @ 1.224 V
GR
GR
GR
GR
Fan
Dump
Gear
Gas
Pump
FIGURE 6. DUMP CYCLE OPTIONS
Przeglądanie stron 14